CCTNG - VACUUM PUMP OIL, DVO-6-4

  • MSDS: CCTNG
  • Manufacturer: J B INDUSTRIES INC
  • Product Name: VACUUM PUMP OIL, DVO-6-4
  • National Stock Number: 9150-00N075173
Product Identification

Product ID:VACUUM PUMP OIL, DVO-6-4
MSDS Date:03/01/1995
FSC:9150
NIIN:00N075173
MSDS Number: CCTNG

Responsible Party
J/B INDUSTRIES INC
601 N FRANSWORTH AVE
AURORA, IL 60507
US

Emergency Phone: 708-851-9444

Info Phone: 708-851-9444

Cage: 32402

Contractor
J/B INDUSTRIES INC
AURORA, IL 60507 US

Telephone: 312-851-9444

Cage: 32402

Ingredients

PETROLEUM LUBRICATING OIL BASE STOCK

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: NONE SPECIFIED BY MANUFACTURER.
CHRONIC: PROLONGED OR REPEATED SKIN CONTACT MAY CAUSE DERMATITIS
(SKIN IRRITATION).
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: IMMEDIATELY FLUSH WITH LARGE QUANTITIES OF WATER FOR AT
LEAST 15 MINUTES AND CALL MD. SKIN: REMOVE EXCESS WITH CLOTH OR
PAPER. WASH THOROUGHLY WITH SOAP AND WATER. INHALATION: REMOVE
VICTIM TO F RESH AIR. CALL MD. INGESTION: CALL MD IMMEDIATELY. DO
NOT INDUCE VOMITING (VOMITING CAN CAUSE ASPIRATION INTO LUNGS
RESULTING IN CHEMICAL PNEUMONIA).

Fire Fighting

Flash Point Method:COC
Flash Point:>425F,>218C
Extinguishing Media:DRY CHEMICAL, WATER FOG, CARBON DIOXIDE, OR FOAM.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . DO NOT USE WATER EXCEPT AS FOG.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:TRANSFER BULK OF MIXTURE INTO ANOTHER
CONTAINER. ABSORB RESIDUE WITH AN INERT MATERIAL SUCH AS EARTH,
SAND, OR VERMICULITE. SWEEP UP AND DISPOSE AS SOLID WASTE IN
ACCORDANCE WITH LOCAL, STATE AND FEDE RAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT HANDLE OR STORE AT TEMPERATURES
OVER 65C (150F).
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR WITH ORGANIC VAPOR
CARTRIDGE IF VAPOR CONCENTRATION EXCEEDS PERMISSIBLE EXPOSURE
LIMIT.
Ventilation:LOCAL EXHAUST IF NECESSARY TO MAINTAIN ALLOWABLE PEL
(PERMISSIBLE EXPOSURE LIMIT) OR TLV (THRESHOLD LIMIT VALUE).
Protective Gloves:NEOPRENE TYPE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:>700F,>371C
Melt/Freeze Pt:M.P/F.P Text:<20F,<-7C
Vapor Pres:0
Vapor Density:<1
Spec Gravity:0.88 (H*2O=1)
Evaporation Rate & Reference:0
Solubility in Water:0 @ 20C
Appearance and Odor:LIGHT AMBER VISCOUS LIQUID, BLAND PETROLEUM ODOR

Stability

Stability Indicator/Materials to Avoid:YES
KEEP AWAY FROM STRONG OXIDIZERS SUCH AS HYDROGEN PEROXIDE, BROMINE AND
CHROMIC ACID.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE AND
SULFUR OXIDES FROM BURNING.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.